TUPFAV —  Tuesday Poster Facilities   (29-Jun-21   11:10—12:10)
Paper Title Page
TUPFAV001 Progress on SRF Linac Development for the Accelerator-Driven Subcritical System at JAEA 372
 
  • B. Yee-Rendón, Y. Kondo, F.M. Maekawa, S.I. Meigo, J. Tamura
    JAEA/J-PARC, Tokai-mura, Japan
 
  To overcome the nuclear waste problem, the Japan Atomic Energy Agency (JAEA) has been developing an accelerator-driven subcritical system (ADS) since the late 1980s. In the JAEA-ADS proposal, an 800 MWth subcritical reactor is driven by a 30 MW cw proton linear accelerator (linac). The biggest challenges for the ADS machines are the high reliability and availability required for their operations. To this end, the present JAEA-ADS linac was redesigned by adopting the current developments in Superconducting Radio-Frequency (SRF) technology. Additionally, we developed a robust lattice to control the beam loss and implemented a fault-tolerance scheme for the fast recovery of SRF cavity failures. This work presents the latest results of the R&D of the JAEA-ADS superconducting linac.  
poster icon Poster TUPFAV001 [0.708 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2021-TUPFAV001  
About • Received ※ 07 June 2021 — Revised ※ 14 July 2021 — Accepted ※ 21 August 2021 — Issue date ※ 26 November 2021
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPFAV002 Calibration of SRF Cavity Voltage by Measurement of Synchrotron Frequency in SuperKEKB 376
 
  • M. Nishiwaki, K. Akai, T. Furuya, T. Kobayashi, S. Mitsunobu, Y. Morita, T. Okada
    KEK, Ibaraki, Japan
 
  Eight SRF cavity modules, which have been operated in KEKB for more than ten years, are stably operating also in SuperKEKB. As for calibration of the cavity voltage Vc, non-negligible discrepancy was observed between the results obtained from two different methods: one is using external Q value (Qext) of pickup ports, and the other is using loaded Q value (QL) of the cavities. The discrepancy comes from inaccuracy of power measurement in high power RF system and uncertainty of the Qext or QL values. In order to solve the discrepancy by improving the accuracy of the calibration for each individual cavity, we investigated a method by measuring synchrotron frequency fs of stored beam. With this method, Vc calibration can be performed without affected by inaccuracy of high-power measurement or uncertainty of the Qext or QL values. The fs measurement studies were carried out in SuperKEKB. With these studies, Vc calibration was obtained with a high accuracy of about 1%. The results are applied to the SuperKEKB operation.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2021-TUPFAV002  
About • Received ※ 21 June 2021 — Revised ※ 13 August 2021 — Accepted ※ 21 August 2021 — Issue date ※ 14 October 2021
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPFAV003 Stable Beam Operation at 33 MV/m in STF-2 Cryomodules at KEK 382
 
  • Y. Yamamoto, M. Akemoto, D.A. Arakawa, A. Araki, S. Araki, A. Aryshev, T. Dohmae, M. Egi, M.K. Fukuda, K. Hara, H. Hayano, Y. Honda, T. Honma, H. Ito, E. Kako, H. Katagiri, R. Katayama, M. Kawamura, N. Kimura, Y. Kojima, Y. Kondou, T. Konomi, M. Masuzawa, T. Matsumoto, S. Michizono, Y. Morikawa, H. Nakai, H. Nakajima, K. Nakanishi, M. Omet, T. Oyama, T. Saeki, H. Sakai, H. Shimizu, S.I. Takahara, R. Ueki, K. Umemori, A. Yamamoto
    KEK, Ibaraki, Japan
  • S. Aramoto
    Hiroshima University, Higashi-Hiroshima, Japan
  • M. Kuriki
    Hiroshima University, Graduate School of Science, Higashi-Hiroshima, Japan
  • Z.J. Liptak
    HU/AdSM, Higashi-Hiroshima, Japan
  • K. Sakaue
    The University of Tokyo, The School of Engineering, Tokyo, Japan
  • A. Yamamoto
    CERN, Meyrin, Switzerland
 
  In STF at KEK, as the operational demonstration of the SRF accelerator for ILC, the STF-2 cryomodules (CM1+CM2a: one and half size CM with 12 cavities) have achieved 33 MV/m as average accelerating gradient with 7 cavities in Mar/2019. After that, one cavity with the lowest performance installed in CM2a was replaced with one N-infused cavity developed for High-Q/High-G R&D between Japan and US. From this April, the beam operation started again and those CMs achieved 33 MV/m as average accelerating gradient with 9 cavities including one N-infused cavity again. This is the very important milestone for ILC. In this report, the detailed results will be presented.  
poster icon Poster TUPFAV003 [3.015 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2021-TUPFAV003  
About • Received ※ 21 June 2021 — Revised ※ 11 July 2021 — Accepted ※ 21 August 2021 — Issue date ※ 01 November 2021
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPFAV004 Surface Polishing Facility for Superconducting RF Cavities at CERN 387
 
  • L.M.A. Ferreira, N.S. Chritin, R. Ferreira, G. Gerbet
    CERN, Geneva, Switzerland
 
  A new SRF cavity polishing facility which covers the needs for present projects like the HL-LHC and its CRAB cavities as well as ongoing and future activities in the frame of the FCC study was commissioned at CERN in 2019. This facility can handle chemical and electrochemical polishing baths, can process both niobium and copper-based cavities on a wide range of geometries, starting at 400 MHz up to 1.3 GHz for elliptical type of cavities and more complex shapes as defined by the DQW and RFD CRAB design. The main subassemblies of this facility are presented. Some important design details and materials choices of the facility will be briefly discussed together with the range of operational parameters. First results on different substrates and geometries are discussed in terms of surface finishing and polishing rate uniformity.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2021-TUPFAV004  
About • Received ※ 17 June 2021 — Revised ※ 09 August 2021 — Accepted ※ 21 August 2021 — Issue date ※ 25 October 2021
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPFAV006 The Superconducting Radio Frequency System of Shenzhen Industrial Synchrotron Radiation Source FacilityRIAL SYNCHROTRON RADIATION SOURCE FACILITY 392
 
  • W. Ma, Y.B. Sun, N. Yuan
    Sun Yat-sen University, Zhuhai, Guangdong, People’s Republic of China
  • L.G. Liu
    SSRF, Shanghai, People’s Republic of China
  • L. Lu, L. Yang, Z.L. Zhang
    IMP/CAS, Lanzhou, People’s Republic of China
 
  Shenzhen industrial synchrotron radiation source is a 3 GeV synchrotron radiation diffraction-limited source. It consists of three parts, linear accelerator, booster, and storage ring. As a basic part of the storage ring, the superconducting radio frequency system provides energy for the beam to supplement the beam power loss caused by synchrotron radiation and higher-order modes, and provide the longitudinal bunch for the electron beam. The superconducting radio frequency cavity of the storage ring consists of two 500 MHz single-cell cavities and a third harmonic 1500 MHz double-cell cavity. This paper will introduce the superconducting cavity, radio frequency amplifier, and low-level radio frequency system in the Shenzhen industrial synchrotron radiation source facility.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2021-TUPFAV006  
About • Received ※ 20 June 2021 — Revised ※ 16 August 2021 — Accepted ※ 21 August 2021 — Issue date ※ 26 November 2021
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)